Heavy Duty Metal Lined Slurry Pump for Mining & Tailings | Kenda Pump

100% compatible with Warman AH series slurry pumps
SPECIFICATIONS:
-Discharge diameters 1” to 18” (25mm to 450mm)
-Capacity: up to 5400 m3/h
-Head: up to 68m
-Speed: 200-3800r/min
-Materials: Cast iron, Ductile iron, High chrome alloy, Natural rubber etc

Kenda KH(R) Series Slurry Pumps Key Features | High Wear-resistant Industrial Transfer Solutions

 

Engineered for the Toughest Abrasive Challenges

The Kenda Metal Lined Slurry Pump is a premier heavy-duty, horizontal centrifugal pump designed specifically to handle high-density, abrasive, and coarse slurries in demanding industrial environments. Built with a robust double-casing structure, this pump ensures maximum safety and operational reliability under high-pressure conditions.

Superior Wear Resistance with High-Chrome Alloy

At the heart of our metal-lined series is the interchangeable A05 High-Chrome Alloy (27% Cr) liners and impellers. Unlike standard pumps, our metallurgy is vacuum-cast to ensure zero porosity, providing exceptional hardness (HRC 60+) and resistance against particle impingement. This significantly extends the mean time between maintenance (MTBM), reducing your total cost of ownership (TCO).

Advanced Hydraulic Design & Versatility

Our engineering team has optimized the impeller vanes to provide the highest hydraulic efficiency without compromising wear life. The pump features:

  • Replaceable Metal Liners: Precision-fit liners are bolted (not glued) for easy replacement and maintenance.

  • Flexible Sealing Options: Choose from Expeller Seals (centrifugal) for waterless operation, Packing Seals, or customized Mechanical Seals for zero-leakage requirements.

  • Multi-Stage Capability: Designed to allow multiple units to be installed in series for high-head, long-distance tailings disposal.

Built for Global Standards

Kenda pumps are engineered to be dimensionally interchangeable with leading international brands, making them the ideal choice for plant upgrades or as high-performance replacements. Whether you are managing mineral processing (copper, gold, iron ore), coal washing, or power plant ash removal, our metal-lined pumps deliver consistent flow rates and superior suction performance in the harshest pH environments.


Kenda KH Slurry Pump Structure


Kenda KH slurry pump diagram: 100% interchangeable with Warman AH parts. High-chrome wet-end for mining.


Features

 

Pump- Cantilever, horizontal centrifugal slurry pump.

Wet parts-Impellers, volutes, liners are made of high chrome alloy or rubber or polyurethane, anti-abrasive, wear resistant and corrosion resistance.

Bearing assembly- Tubular structure bearing assembly, design of high capacity bearing. Grease lubrication, oil lubrication helps to adapt to different operating conditions.

Shaft seal- Sealed by packing or centrifugal.

Pump exit position- Based on 450 interval, rotating eight different angles of installation.


Kenda KH Series Slurry Pump Technical Specifications Chart

Model

Max. Motor Power (kW)

Material

Clear   Water Performance

Impel.

Dia.

(mm)

Liner

Impeller

Capacity  Q (m³/h)

Head

H(m)

Pump Speed

n(r/min)

Max. Eff.

η%

NPSH

(m)

KH-1B

15

M

M

12.6-28.8

6-68

1200-3800

40

2-4

152

KHR-1B

15

RU

RU

10.8-25.2

7-52

1400-3400

35

2-4

152

KHH-1C

30

M

M

16.2-34.2

25-92

1400-2200

20

2-5.5

330

KH-1.5B

15

M

M

32.4-72

6-58

1200-3200

45

3.5-8

184

KHR-1.5B

15

RU

RU

25.2-54

5.5-41

1000-2600

50

2.5-5

178

KH-2C

30

M

M

39.6-86.4

12-64

1300-2700

55

4-6

214

KHR-2C

30

RU

RU

36-75.6

13-46

1300-2300

60

2-4

213

KHH-2D

60

M

M

68.4-136.8

25-87

850-1400

47

3-7.5

457

KH-3C

30

M

M

86.4-198

9-52

1000-2200

71

4-6

245

KH-3D

60

M

M

86.4-198

9-52

1000-2200

71

4-6

245

KHR-3C

30

RU

RU

79.2-180

5-34.5

800-1800

59

3-5

245

KHR-3D

60

RU

RU

79.2-180

5-34.5

800-1800

59

3-5

245

KHH-3E

120

M

M

126-252

12-97

600-1400

50

2-5

508

KH-4D

60

M

M

162-360

12-56

800-1550

65

5-8

365

KH-4E

120

M

M

162-360

12-56

800-1550

65

5-8

365

KHR-4D

60

RU

RU

144-324

12-45

800-1350

65

3-5

365

KHR-4E

120

RU

RU

144-324

12-45

800-1350

65

3-5

365

KHH-4F

260

M

M

324-720

30-118

600-1000

64

3-8

711

KHH-6S

560

M

M

468-1008

20-94

500-1000

65

4-12

711

KH-6E

120

M

M

360-828

10-61

500-1140

72

2-9

510

KH-6R

300

M

M

360-828

10-61

500-1140

72

2-9

510

KHR-6E

120

RU

RU

32-720

7-49

400-1000

65

5-10

510

KHR-6R

300

RU

RU

32-720

7-49

400-1000

65

5-10

510

KH-8ST

560

M

M

612-1368

11-61

400-850

71

4-10

686

KHR-8ST

560

RU

RU

540-1188

12-50

400-750

75

4-12

686

KM-8E

120

M

M

540-1440

14-60

600-1000

73

4-10

549

KM-8R

300

M

M

540-1440

14-60

600-1000

73

4-10

549

KH-10ST

560

M

M

936-1980

7-68

330-800

82

6

762

KHR-10ST

560

RU

RU

720-1620

7-45

300-650

80

2.5-7.5

762

KH-12ST

560

M

M

1260-2772

13-63

300-600

77

3-10

965

KHR-12ST

560

RU

RU

1152-2520

13-44

300-500

79

3-8

965

KH-14TU

1200

M

M

1368-3060

11-63

250-550

79

4-10

1067

KH-16TU

1200

M

M

2160-5054

8-66

200-500

80

4.5-9

1245

KH-18TU

1200

M

M

2520-5400

13-57

200-400

85

5-10

1370


Kenda KH Series Slurry Pump Material Options Chart

Slurry Pump Parts

Material

Specification

HRC

Application

Material Code

Volute Liner, Impeller

Hard Metal

23%-30% chrome white iron

≥56

Used for higher wear conditions with PH between   5 to 12

A05

14%-18% chrome white iron

≥59

Used for higher wear conditions

A07

27%-29% chrome white iron

43

Used for lower PH conditions especially for FGD.   Its also can be used for low-sour conditions and desulfuration with PH no less   than 4.

A49

Rubber

Standard Impeller Rubber



R08

Standard Liner Rubber



R26

Natural rubber (soft)



R33

Natural rubber



R55

Hypalon



S31

PU

Polyurethane



U01

Expeller, Expeller Ring

Metal

23%-30% chrome white iron

≥56

Used for higher wear conditions with PH between   5 to 12

A05

Grey iron



G01

Stuffing Box

Metal

23%-30% chrome white iron

≥56

Used for higher wear conditions with PH between   5 to 12

A05

Grey iron



G01

Frame Plate, Cover Plate, Bearing House, Base

Metal

Grey iron



G01

Ductile iron



D21

Shaft

Metal

Carbon Steel



E05

Shaft Sleeve, Lantern Ring, Resctrictor Neck Ring,   Gland Bolt

Stainless Steel

4Cr13



C21

304 SS



C22

316 SS



C23

Joint Rings, Seals

Rubber

Butyl rubber



S21

EPDM rubber



S01

Nitrile



S10

Hypalon



S31

Neoprene



S44, S42

Viton



S50

Metal Lined Slurry Pump Applications

Kenda KH slurry pump, 100% interchangeable with Warman AH, in gold mining tailings circuit.


• Mining

• Mineral processing

• Coal prep

• Cyclone feeds

• Tunnel

• Chemical slurries

• Tailings

• Mill grinding

• Ash handing

• Paper and Pulp

• Waste sludge

• Coarse sand

• Lime mud

• Phosphoric acid

• Dredging

• Construction

• Alumina Industry

• Power Plant

• Potash Fertilizer Plant

• Other industries


Looking for durable metal lined slurry pumps? Kenda's A05 high-chrome alloy pumps offer superior abrasion resistance for mining and mineral processing. 100% Interchangeable with Warman AHRequest a quick quote today!

 

Frequently Asked Questions (FAQ)


Q1: How do I choose between Metal Lined and Rubber Lined Slurry Pumps?

A: The choice primarily depends on the particle size and shape of your slurry.

  • Metal Lining (High-Chrome  Alloy):  Best for handling large, coarse, or sharp particles and high-impact conditions  (e.g., primary mining or gravel). It offers superior hardness (HRC 60+).

  • Rubber Lining: Ideal for fine particles (typically <5mm) and highly corrosive or acidic environments (pH 2-13). If your application involves heavy mining tailings or crushed ore with sharp edges, a Metal Lined Slurry Pump is usually the more durable choice.

Q2: Why is my pump impeller wearing out faster than expected?

A: Accelerated wear is often caused by three main factors:

  1. Operating Away from BEP: If the pump operates too far from its Best Efficiency Point, internal turbulence increases, causing localized erosion.

  2. Material Mismatch: The slurry's hardness might exceed the limits of the impeller alloy.

  3. Cavitation: Insufficient suction pressure creates vapor bubbles that implode on the metal surface, pitting the impeller. Tip: Regularly adjust the impeller clearance to maintain high efficiency and      reduce backflow erosion.

Q3: Are Kenda Metal Liners interchangeable with other major brands?

A: Yes. Kenda slurry pumps are engineered to be dimensionally interchangeable with international industry standards. Our wet-end parts—such as impellers, volute liners, and throat bushes—fit seamlessly into existing pump casings of similar designs. This allows you to upgrade to Kenda’s high-performance A05 wear-resistant parts without replacing your entire pump system, significantly reducing maintenance costs.

Q4: How can I extend the service life of a High-Chrome Alloy Slurry Pump?

A: Proactive maintenance is key to longevity:

  • Impeller Adjustment: Periodically adjust the  gap between the impeller and the throatbush to compensate for wear and maintain hydraulic performance.

  • Seal Maintenance: Ensure the expeller seal  is properly lubricated or that the gland packing has the correct flow of cooling water to prevent slurry from entering the shaft sleeve.

  • Avoid Dry Running: Never run the pump without  fluid, as this causes rapid heat buildup and can damage the mechanical seals or internal liners.

Q5: What is the maximum solid size a Kenda Metal Lined Pump can handle?

A: The maximum allowable particle size depends on the specific pump model and its discharge diameter. Generally, our metal-lined pumps are designed with wide internal passages to handle solids up to 50% to 80% of the discharge pipe diameter, depending on the particle concentration and shape. For specific spherical clearance data, please consult our engineering team with your slurry analysis.

 

Case Studies

 

Case Study 1: Improving Efficiency in a Coal Preparation Plant (Australia)

Industry: Coal Washing & Preparation

Challenge: An Australian coal plant struggled with high energy consumption and leaking shaft seals in their heavy-media circuit. They needed a reliable, high-efficiency solution that could integrate into their existing pipeline without costly modifications.

Our Solution: Kenda provided dimensionally interchangeable metal lined pumps with optimized Expeller Seals (Centrifugal Seals). This allowed the plant to operate without seal water, preventing slurry dilution.

Results:

Perfect Fit: 100% compatibility with existing piping, reducing installation time by 70%.

Energy Efficiency: The optimized hydraulic design led to a 12% reduction in power consumption.

Zero Leakage: The expeller seal eliminated the need for gland water, saving thousands of gallons of water daily.

 

Case Study 2: High-Head Tailings Disposal for an Iron Ore Project

Industry: Iron Ore Mining

Challenge: The project required transporting high-density iron ore tailings over a distance of 3km with a vertical lift of 60 meters. A single-stage pump could not handle the required head pressure.

Our Solution: Kenda engineers designed a multi-stage pump system using three 6/4D-MAH Metal Lined Slurry Pumps installed in series. The double-casing design of our pumps ensured they could safely withstand the high internal pressures of a multi-stage setup.

Results:

Steady Performance: The system maintained a consistent flow rate of 350 m³/h at the required pressure.

Durability: Despite the high-pressure environment, the metal liners showed minimal signs of wear after 4,000 hours of continuous operation.

Safety: The robust outer casing provided an extra layer of protection for onsite workers.


Categories